Quantcast
Channel: ProjectWise Design Integration Wiki
Viewing all articles
Browse latest Browse all 1890

Slow Security Dialog

$
0
0
Current Revision posted to Content Management - Wiki by Elisa Pry on 8/16/2013 2:38:37 PM

  
 Applies To 
  
 Product(s):ProjectWise V8 XM Edition
 Version(s):08.09.04.63
 Environment: N/A
 Area: Explorer
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Problem Description

Opening the Security Tabs of the Properties Dialog takes 8 to 10 minutes.

Solution

Apply “i_dms_proj_HDR” index.  This query is used by the ProjectWise server to update the project access control cache on the ProjectWise server.  This operation basically happens on Folder creates, folder deletes and even browsing.  We are constantly checking the database to ensure that the cache is in synch with the db.  Any one of these operations should trigger the SQL statement.