Current Revision posted to ProjectWise Design Integration Wiki by Dana Guthrie on 9/13/2022 7:42:16 PM
Product(s): | ProjectWise Explorer Client V8i | ||
Version(s): | 08.11.11.605 | ||
Environment: | Windows 7 64 bit | ||
Area: | Integration - AutoCAD | ||
Subarea: | Enable / Disable integration |
Problem
User is getting the following error when opening AutoCad files from ProjectWise Explorer V8i SS4 version 08.11.11.605. The user has AutoCad 2014 loaded with the ProjectWise Integration Module for Autodesk AutoCAD 2104 version 08.11.11.749
"Exception in idacad19_1odma.arx ARX Command"
"Unhandled Exception C0000005 (Access Violation Reading 0x0000) at address 9718EC58h"
Solution
Removing the ProjectWise Integration Module for Autodesk AutoCAD 2104 version 08.11.11.749 and loading the ProjectWise Integration Module for AutoCAD 2014 version 08.11.11.855 fixed the issue.
Original Author: | Van Kendall |
Tags: Enable / Disable integrationWindows 7 64 bit, 08.11.11.590, Integration - AutoCAD, ProjectWise, ProjectWise Explorer Client V8i, en, SELECTsupport