Current Revision posted to ProjectWise Design Integration Wiki by Dana Guthrie on 9/30/2022 5:59:04 PM
Product(s): | ProjectWise Explorer Client | ||
Version(s): | 08.11.11.559 | ||
Area: | Integration - MicroStation | ||
Subarea: | Open / Close / Save As | ||
Original Author: | Molly Watts, Bentley Technical Support Group |
Error or Warning Message
The procedure entry point GetAttributeName...could not be located in the dynamic link library idattm.dll
Followed by this error in MicroStation:
"Error initializing ODMA"
Explanation
There are two different versions of ProjectWise installed (PW XM and PW v8i) and the version currently opened is not the "active" version of ProjectWise
How to Avoid
1. Run the Versionswitch command to change the active version
...\ProjectWise\bin\versionSwitch.vbs /811
...\ProjectWise\bin\versionSwitch.vbs /89
See Also
Tags: Open / Close / Save As, Integration - MicroStation, error message, ProjectWise Explorer Client, SELECTsupport