Current Revision posted to ProjectWise Design Integration Wiki by Dana Guthrie on 10/7/2022 7:40:55 PM
Product(s): | ProjectWise V8i | ||
Version(s): | 08.11.05.37 | ||
Area: | Connection Svr-PW Gateway | ||
Original Author: | Bentley Technical Support Group |
Problem Description
Setting up ProjectWise Gateway server. All configurations appeared correct, but datasoures were not being published.
Solution
In the Name resolution section of the dmskrnl.cfg on the Gateway server, move the comments to a different line
it was:
IP=Name ;comment
the comment needs to be on a separate line:
;comment
IP=Name
See Also
External Links
Bentley Technical Support KnowledgeBase
Comments or Corrections?
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
Tags: SELECTservices, ProjectWise