Problem Description
Opening the Security Tabs of the Properties Dialog takes 8 to 10 minutes.
Solution
Apply “i_dms_proj_HDR” index. This query is used by the ProjectWise server to update the project access control cache on the ProjectWise server. This operation basically happens on Folder creates, folder deletes and even browsing. We are constantly checking the database to ensure that the cache is in sync with the db. Any one of these operations should trigger the SQL statement.