Revision 1 posted to Content Management - Wiki by Molly Watts on 12/6/2013 3:54:28 PM
Applies To | |||
Product(s): | ProjectWise Dynamic Composition Server | ||
Version(s): | |||
Environment: | N/A | ||
Area: | Administrator | ||
Subarea: | |||
Original Author: | Molly Watts, Bentley Technical Support Group | ||
Error or Warning Message
generic error while running the Configuration Wizard
Object reference not set to an instance of an object when trying to uninstall iCS when its in this state
Explanation
The installation of iCS will finish, and then attempt to kick off the configuration wizard. The first step of the configuration is to create a printer, and in this case the Windows Print Spooler service was disabled
How to Avoid
In Windows Services, set Print Spooler to startup "Automatic"
Start the Print Spooler service
Rerun the configuration wizard (Start-Programs -Bentley-ProjectWise V8i (SELECTseries 4)-Bentley i-model Composition Server for PDF-Bentley i-model Composition Server Configuration)
Tags: Administrator, SELECTsupport, ProjectWise Dynamic Composition Server, Error Message, iCS for PDF