"generic error" running Bentley i-model Composition Server Configuration

$
0
0
Revision 1 posted to Content Management - Wiki by Molly Watts on 12/6/2013 3:54:28 PM

  
 Applies To 
  
 Product(s):ProjectWise Dynamic Composition Server
 Version(s):
 Environment: N/A
 Area: Administrator
 Subarea: 
 Original Author:Molly Watts, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

generic error while running the Configuration Wizard

Object reference not set to an instance of an object when trying to uninstall iCS when its in this state

Explanation

The installation of iCS will finish, and then attempt to kick off the configuration wizard.  The first step of the configuration is to create a printer, and in this case the Windows Print Spooler service was disabled

How to Avoid

 

  1. In Windows Services, set Print Spooler to startup "Automatic"

  2. Start the Print Spooler service

  3. Rerun the configuration wizard (Start-Programs -Bentley-ProjectWise V8i (SELECTseries 4)-Bentley i-model Composition Server for PDF-Bentley i-model Composition Server Configuration)

 