Revision 1 posted to Content Management - Wiki by Molly Watts on 12/20/2013 3:39:18 PM
Applies To | |||
Product(s): | ProjectWise Integration Server | ||
Version(s): | 08.11.11.111 | ||
Environment: | N/A | ||
Area: | ProjectWise Administrator | ||
Subarea: | Administrative Tools | ||
Original Author: | Molly Watts, Bentley Technical Support Group | ||
Error or Warning Message
Error 58209 Can not create document Cannot format data string: non-negative integer number is required
Explanation
The environment was configured with a document code, with a placeholder attribute. The attribute used as the placeholder was configured with a format string that did not comply with the data that was being entered (%3u is expecting an integer)
How to Avoid
In the attribute settings, modify the format string to comply with the data that will be entered into the attribute or remove the format string all together.
- note: there is a known problem with clearing out the format string, to workaround the issue type only a space in the field before clicking apply or ok