User is trying to format a number for hi... (Solution 500000101441)

$
0
0
Current Revision posted to Content Management - Wiki by Bill on 6/10/2014 5:19:04 PM

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.559
 Environment: N\A
 Area: Document Code
 Subarea: N\A
 Original Author:Bill Kenney, Bentley Technical Support Group
  

Problem

User is trying to format a number for his document code, but the format
string is not working as intended. %4u was bringing out -1 and not 0001
with the leading zeros.

Product: ProjectWise Client V8i
Version: 08.11.11.111
Area: Explorer, Problem ID#: 90686, PROBLEMSOLVING



Solution

User changed the environmental attribute in the SQL database to Varchar
instead of Integer, and that corrected the issue.