Problem
Move Temp async extraction folder for full text indexing
Product: ProjectWise Server V8i
Version: 08.11.11.111
Area: Index Server, Problem ID#: 88714, GENERALINFORMATION
Solution
Perform the following in this order:
1. Stop the Microsoft indexing service and PW Orchestration service
2. In the registry editor go the following key and change the path
3. HKEY_LOCAL_MACHINE\SOFTWARE\Bentley\ProjectWise\Automated File
4. Processing\ExtractionTempDir
5. Restart the services
See Also