Move Temp async extraction folder

$
0
0
Current Revision posted to Content Management - Wiki by Dana Guthrie on 7/2/2014 10:46:47 PM

  
 Applies To 
  
 Product(s):ProjectWise Integration Server
 Version(s):08.11.11.111
 Environment: N\A
 Area: Integration / Caching /Gateway
 Subarea: MISC
 Original Author:Dana Guthrie, Bentley Technical Support Group
  

Problem

Move Temp async extraction folder for full text indexing

Product: ProjectWise Server V8i
Version: 08.11.11.111
Area: Index Server, Problem ID#: 88714, GENERALINFORMATION



Solution

Perform the following in this order:

1. Stop the Microsoft indexing service and PW Orchestration service
2. In the registry editor go the following key and change the path
3. HKEY_LOCAL_MACHINE\SOFTWARE\Bentley\ProjectWise\Automated File
4. Processing\ExtractionTempDir
5. Restart the services



See Also