Quantcast
Channel: ProjectWise Design Integration Wiki
Viewing all articles
Browse latest Browse all 1890

Revit autologins to datasource

$
0
0
Current Revision posted to Content Management - Wiki by Jessica Gamble on 9/18/2014 7:45:46 PM

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.559
 Environment: N/A
 Area: Integration - Revit
 Subarea: Auto Login to datasource
 Original Author:Mantas Nauseda, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

When using the ProjectWise application (like AutoCAD, Revit or MicroStation) and trying to open the document (from inside of application) it logs in automatically to one of the datasources.
Opening ProjectWise Network Configuration does not show any settings of autologin defined.

Reason

Most likely in previous versions of ProjectWise the autologin settings were saved in the Crrent User registry (HKCU). After upgrading to ProjectWise SS4 Refresh Update the Network Configuration Settings requires the administrator rights to start and as a result the settings are saved/loaded from the Local Machine (HKLM).

This results that the Network Configuration does not show any settings defined, but the application loads these settings from HKCU and logs in to datasource automatically.

Steps to Resolve

  1. Open Registry editor
  2. Navigate to: HKEY_CURRENT_USER\Software\Bentley\ProjectWise iDesktop Integration\08.11\AutoLogin
  3. This key stores all autologin details
  4. Delete all the autologin settings from current user
  5. If needed use the ProjectWise Network configuration to define the required autologin settings.

 

Tags: AutoCAD integration, auto login, Integration - Revit, autologin, Open / Close / Save As, registry, Revit, ProjectWise Explorer Client, SELECTsupport, Problem Solving