Quantcast
Channel: ProjectWise Design Integration Wiki
Viewing all articles
Browse latest Browse all 1890

Last Error 11502 copying files into ProjectWise

$
0
0
Current Revision posted to Project Delivery: Content Management Wiki by Thomas Hess on 8/2/2016 8:55:29 PM

 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.559
 Area: MISC
 Original Author:Jacquelene Smiro, Bentley Technical Support Group

Problem Description

Last Error 11502 when trying to copy files from network into ProjectWise.

Steps to Resolve

  1. Check PW Network Configuration settings to ensure that Prevent UDP is checked for both DNS and Datasource listing tabs. If not hard checked, do so.

  2. Copy files from network to desktop locally.

  3. Received "windows" error that there was not permissions to copy files and was given option by windows to skip those files. Once we were able to skip the files in question was then able to then copy files into folder in ProjectWise successfully.

Tags: 08.11.11.559, MISC, ProjectWise Explorer Client, SELECTsupport, Problem Solving, Last error