Current Revision posted to Content Management - Wiki by Molly Watts on 8/7/2013 8:44:06 PM
Applies To | |||
Product(s): | ProjectWise Explorer Client | ||
Version(s): | 08.11.11.559 | ||
Environment: | N/A | ||
Area: | Integration - MicroStation | ||
Subarea: | Open / Close / Save As | ||
Original Author: | Molly Watts, Bentley Technical Support Group | ||
Error or Warning Message
The prodedure entry point ?GetAttributeName...could not be located in the dynamic link library idattm.dll
followed by this error in MicroStation
Error initializing ODMA
Explanation
There are two different versions of ProjectWise installed (PW XM and PW v8i) and the version currently opened is not the "active" version of ProjectWise
How to Avoid
1. run the versionswitch command to change the active version
...\ProjectWise\bin\versionSwitch.vbs /811
...\ProjectWise\bin\versionSwitch.vbs /89
See Also