Error opening DGN from ProjectWise

$
0
0
Current Revision posted to Content Management - Wiki by Molly Watts on 8/7/2013 8:44:06 PM

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.559
 Environment: N/A
 Area: Integration - MicroStation
 Subarea: Open / Close / Save As
 Original Author:Molly Watts, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

The prodedure entry point ?GetAttributeName...could not be located in the dynamic link library idattm.dll

followed by this error in MicroStation

Error initializing ODMA

Explanation

There are two different versions of ProjectWise installed (PW XM and PW v8i) and the version currently opened is not the "active" version of ProjectWise

How to Avoid

1. run the versionswitch command to change the active version

...\ProjectWise\bin\versionSwitch.vbs /811

...\ProjectWise\bin\versionSwitch.vbs /89

 

See Also

http://communities.bentley.com/products/projectwise/content_management/f/342986/p/74766/200549.aspx#200549

 

 