Distribution Services does not work with the set file enabled

Current Revision posted to Content Management - Wiki by mantas.nauseda on 11/28/2013 6:14:43 AM

Image may be NSFW.
Clik here to view.

  
 Applies To 
  
 Product(s):ProjectWise Dynamic Composition Server (Distribution Services)
 Version(s):08.11.11.559
 Environment: N/A
 Area: PDF
 Subarea: 
 Original Author:Mantas Nauseda, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

When trying to run the Distribution Service job that has the set (InterPlot Settings file) enabled it gives the error (when using Bentley Navigator as a print engine):
Failed -- IPARMENG, The MicroStation IPARM engine did not complete successfully.
- Milepost code: 0

Image may be NSFW.
Clik here to view.

And error (when using MicroStation as a print engine):
Failed -- CMDERR, executed ipmstnsrvm, which failed

Image may be NSFW.
Clik here to view.

When trying to use the same ProjectWise document and the same settings file in the InterPlot Organizer it worked fine without any errors.

Reason

When the set file is used in the Distribution Job the Print Engine process is started with the Current Directory that is the Distribution service working directory (a shared folder on the network, for example: \\ server_name.domain.com\ds_working\1\282_35)

User had the system Path added that syntax was not correct. One of the paths was added like: \c:\windows. This way when the print engine (MicroStation or Navigator) was locating the required dll files it was trying to load the dll from the path: \\ server_name.domain.com\ds_working\1\282_35c:\windows
The syntax of the path is not correct and it failed to load the dll. The whole process stopped at this stage.

Steps to Resolve

To resolve the issue the System Path was fixed (backslash was removed from: \c:\windows to: c:\windows)

 

Tags: PDF, ProjectWise Dynamic Composition Server, path, Distribution Services, SELECTsupport, Problem Solving

This file 'C3D 2012.CivilDSProj' format is unsupported

Current Revision posted to Content Management - Wiki by Molly Watts on 12/4/2013 7:47:49 PM

Image may be NSFW.
Clik here to view.

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.559
 Environment: N/A
 Area: Integration - Civil 3D
 Subarea: Data Shortcuts
 Original Author:molly watts, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

This file 'C3D 2012.CivilDSProj' format is unsupported

Explanation

User was trying to open the CivilDSProj file directly via Civil3D

How to Avoid

 

    1. The recommended workflow is to open the master file from ProjectWise, which will copy out the Data Shortcuts files automattically.

 

 

See Also

http://communities.bentley.com/products/projectwise/content_management/m/mediagallery/228167.aspx

Tags: Integration - Civil 3D, error message, ProjectWise Explorer Client, Data Shortcuts, SELECTsupport

Managed Workspace config file changes are not sticking

Current Revision posted to Content Management - Wiki by Dana Guthrie on 12/5/2013 5:29:47 PM

Image may be NSFW.
Clik here to view.

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.559
 Environment: N/A
 Area: MISC
 Subarea: 
 Original Author:Dana Guthrie, Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Background

Changes to files in ProjectWise managed workspace are not updating the workspace on the local machine

User had changed a configuration file on his local system, then renamed the original in ProjectWise to .old and then dropped the newly edited one in. 

When he opens a dgn file that is in a folder with the workspace assigned the changes he made in the workspace are not there.  It seems to be reading the old file

Explanation

Projectwise knows that the file he renamed is part of a configuration block and when he changed the name in PWE, PW also changed the name in the configuration block to reference the .old file

Steps to Resolve

  • Remove the new file
  • Rename the .old file to the original name
  • Go to the properties of that file and using the advance button import the new file.

 

 

Tags: Manage Workspace, ProjectWise Explorer Client

"generic error" running Bentley i-model Composition Server Configuration

Revision 1 posted to Content Management - Wiki by Molly Watts on 12/6/2013 3:54:28 PM

Image may be NSFW.
Clik here to view.

  
 Applies To 
  
 Product(s):ProjectWise Dynamic Composition Server
 Version(s):
 Environment: N/A
 Area: Administrator
 Subarea: 
 Original Author:Molly Watts, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

generic error while running the Configuration Wizard

Object reference not set to an instance of an object when trying to uninstall iCS when its in this state

Explanation

The installation of iCS will finish, and then attempt to kick off the configuration wizard.  The first step of the configuration is to create a printer, and in this case the Windows Print Spooler service was disabled

How to Avoid

 

  1. In Windows Services, set Print Spooler to startup "Automatic"

  2. Start the Print Spooler service

  3. Rerun the configuration wizard (Start-Programs -Bentley-ProjectWise V8i (SELECTseries 4)-Bentley i-model Composition Server for PDF-Bentley i-model Composition Server Configuration)

 

Tags: Administrator, SELECTsupport, ProjectWise Dynamic Composition Server, Error Message, iCS for PDF

Error 58502 deleting document

Current Revision posted to Content Management - Wiki by Molly Watts on 12/6/2013 9:57:43 PM

Image may be NSFW.
Clik here to view.

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.559
 Environment: N/A
 Area: GUI
 Subarea: 
 Original Author:Molly Watts, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

Error 58502: Error deleting document. user is not an administrator

Explanation

User had full rights on the document, also had document delete user setting turned on.  Datasource settings were configured that only Administrators could delete.

How to Avoid

 

  1. In ProjectWise Administrator, log into the datasource
  2. Right click on datasource name-properties
  3. Settings tab
  4. Change global delete restrictions to "default"

 

 

See Also

 

Tags: error message, ProjectWise Explorer Client, GUI, SELECTsupport

SSO Clients are not silently re-authenticated to the datasource

Current Revision posted to Content Management - Wiki by john.lee on 12/6/2013 11:33:05 PM

Image may be NSFW.
Clik here to view.

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.423
 Environment: Windows 7 64 bit
 Area: MISC
 Subarea: 
 Original Author:John Lee, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

Cached SSO domain login credentials are not expired is failing. SSO Clients are not silently re-authenticated to the datasource.

Findings

In the failed case: 

integrated MicroStation SSO credentials are expiring.  The Default lifetime for Client-side cached  login credential used to silently re-authenticate a client to the Integration  Sever is not working correctly and affecting the cached SSO/domain login. The SSO credentials should not expire.

As referenced to the cfg file, cached SSO/domanin login credentials are not expired:

; Default lifetime (in seconds) for client-side cached login credentials, used to

; silently re-authenticate a client to the Integration Server in the event of a

; network disconnect. When using ProjectWise authentication, after this timeout

; occurs clients will be required to re-input their ProjectWise login credentials.

; A value of 0 (or less) is illegal. Use the "User Credential Expiration Policy"

; General user settings (in the ProjectWise Administrator) to set the policy for

; user expirations.

;

; If this setting is commented out, a default expiration value of 10 hours is used.

; Note that this applies to ProjectWise authenticationonly -- cached SSO/domain login

; credentials are not expired.

;

UserLoginTokenTimeout=36000

 

The failure has been confirmed using  MicroStation SS3 version 08.11.09.357 integrated with PWExplorer  version
08.11.11.567 (see fig 1)

Image may be NSFW.
Clik here to view.

Steps to Resolve

Manually reconnect the MicroStation session to ProjectWise by clicking the <OK> button in fig 1 above.

Tags: 08.11.11.423, MISC, ProjectWise Explorer Client, SELECTsupport, Problem Solving

ProjectWise Web scroll bar too low to view attributes

Current Revision posted to Content Management - Wiki by Bill on 12/10/2013 10:07:45 PM

Is the ProjectWise Explorer web client scroll bar too low to view environment attributes ?  There is a workaround for this that involves editing an xml document on the Web Server to bring the scroll bar up and close, in the view, to see which attributes are in what columns.   The solution for the scroll bar is to edit the default.aspx page, and change the two lines that have “ExpandWithContent" = “true”” to “false”. 

This file is often found in the C:\Inetpub\wwwroot\Default directory

 

"Network Path Not Found" when running i-model Composition Server job

Current Revision posted to Content Management - Wiki by sboniwell on 12/11/2013 1:11:38 AM

Image may be NSFW.
Clik here to view.

  
 Applies To 
  
 Product(s):ProjectWise Dynamic Composition Server
 Version(s):
 Environment: Window Server 2008 64 bit, Windows 7 64 bit, Windows Server 2008 R2
 Area: PDF
 Subarea: 
 Original Author:Steve Boniwell, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

When running an i-model Composition job from either ProjectWise Explorer or i-model Composition Server Administrator, an error message "Network Path Not Found" is displayed and the job is not processed.

Explanation

The working directory that is set for i-model Composition Server is not accessible.

How to Avoid

Ensure that the Working Directory specified is accessible.

Tags: PDF, ProjectWise Dynamic Composition Server, Windows 7 64 bit, error message, Windows Server 2008 R2, Window Server 2008 64 bit, SELECTsupport

55037 file not found on server

Revision 1 posted to Content Management - Wiki by Dana Guthrie on 12/17/2013 7:51:14 PM

Image may be NSFW.
Clik here to view.

  
 Applies To 
  
 Product(s):ProjectWise Integration Server
 Version(s):08.11.11.111
 Environment: N/A
 Area: Integration / Caching /Gateway
 Subarea: MISC
 Original Author:Dana Guthrie, Bentley Technical Support Group

 

 

 

 

 

Error or Warning Message

Last Error 55037 file not found on server

Explanation

User has made a copy of the production database and placed it in a development environment. He change the storage area to point to an old set of files that he had previously used in a test.

When he checks out or tries to open a file he gets error 55037 file not found on server.

How to Avoid

Had user check the storage area for the file and it was there

Had user create a new file and then check that it gets placed in the same location, and it did.

Checked the size of the file to what ProjectWise thinks it should be and it is the same.

User realized that the files he was using had versions and the file dataset he was using did not have the updated versions.

Once he copied the production files to the development environment he was able to open the files.

 

Tags: Appl Svr-Integration Svr

ProjectWise Integration Server

Current Revision posted to Content Management - Wiki by Michael Dougherty on 12/17/2013 10:01:43 PM

ProjectWise Administrator - ProjectWise Integration Server

Current Revision posted to Content Management - Wiki by Michael Dougherty on 12/17/2013 10:02:38 PM

ProjectWise Explorer Client

Current Revision posted to Content Management - Wiki by Dana Guthrie on 12/20/2013 2:04:07 PM

Integration - DGN Platform - ProjectWise Explorer Client

Current Revision posted to Content Management - Wiki by Dana Guthrie on 12/20/2013 2:04:09 PM

Reference Scan for Microstation J files

Revision 1 posted to Content Management - Wiki by Dana Guthrie on 12/20/2013 2:04:09 PM

Image may be NSFW.
Clik here to view.

Applies To
Product(s):ProjectWise Explorer Client
Version(s):08.11.11.559
Environment: N/A
Area: Integration - DGN Platform
Subarea: Scan for References and Links
Original Author:Dana Guthrie, Bentley Technical Support Group

 

 

 

 

 

 

Problem Description

XXXXXXX(Provide a complete description of the problem. Should be written in the "first person" [e.g., "When I compute the model�"])XXXXXXX

Steps to Resolve

  1. XXXXXXX(add more steps as needed)XXXXXXX
Tags: Integration - DGN Platform, Scan for References and Links, ProjectWise Explorer Client, SELECTsupport, Problem Solving

Error 58209 Can not create document

Revision 1 posted to Content Management - Wiki by Molly Watts on 12/20/2013 3:39:18 PM

Image may be NSFW.
Clik here to view.

Applies To
Product(s):ProjectWise Integration Server
Version(s):08.11.11.111
Environment: N/A
Area: ProjectWise Administrator
Subarea: Administrative Tools
Original Author:Molly Watts, Bentley Technical Support Group

Error or Warning Message

Error 58209 Can not create document  Cannot format data string: non-negative integer number is required

Explanation

The environment was configured with a document code, with a placeholder attribute.  The attribute used as the placeholder was configured with a format string that did not comply with the data that was being entered (%3u is expecting an integer)

Image may be NSFW.
Clik here to view.

How to Avoid

    1. In the attribute settings, modify the format string to comply with the data that will be entered into the attribute or remove the format string all together.

      1. note: there is a known problem with clearing out the format string, to workaround the issue type only a space in the field before clicking apply or ok


Installation - ProjectWise Explorer Client

Current Revision posted to Content Management - Wiki by JackiS on 1/2/2014 9:17:24 PM

Registry keys for ProjectWise Integration

Revision 1 posted to Content Management - Wiki by JackiS on 1/2/2014 9:17:24 PM

Image may be NSFW.
Clik here to view.

Applies To
Product(s):ProjectWise Explorer Client
Version(s):08.11.11.559
Environment: N/A
Area: Installation
Subarea:
Original Author:Jacquelene Smiro, Bentley Technical Support Group

 

 

 

 

 

 

Problem Description

XXXXXXX(Provide a complete description of the problem. Should be written in the "first person" [e.g., "When I compute the model�"])XXXXXXX

Steps to Resolve

  1. XXXXXXX(add more steps as needed)XXXXXXX
Tags: installation, ProjectWise Explorer Client, SELECTsupport, Problem Solving

Security and Permissions - ProjectWise Explorer Client

Current Revision posted to Content Management - Wiki by Molly Watts on 1/9/2014 4:43:00 PM

Change Permissions right

Revision 1 posted to Content Management - Wiki by Molly Watts on 1/9/2014 4:43:00 PM

Image may be NSFW.
Clik here to view.

Applies To
Product(s):ProjectWise Explorer Client
Version(s):08.11.11.559
Environment: N/A
Area: Security and Permissions
Subarea:
Original Author:Molly Watts, Bentley Technical Support Group

 

 

 

 

 

 

Problem Description

XXXXXXX(Provide a complete description of the problem. Should be written in the "first person" [e.g., "When I compute the model�"])XXXXXXX

Steps to Resolve

  1. XXXXXXX(add more steps as needed)XXXXXXX
Tags: Security and Permissions, ProjectWise Explorer Client, SELECTsupport, Problem Solving

Security - ProjectWise Web Server

Current Revision posted to Content Management - Wiki by Molly Watts on 1/9/2014 9:12:26 PM