Scan for references tool does not work on Microstation J files

$
0
0
Current Revision posted to Content Management - Wiki by Vickie.Hewitt on 2/17/2014 7:47:37 PM

Applies To
Product(s):ProjectWise Explorer Client
Version(s):08.11.11.559
Environment: N/A
Area: Integration - DGN Platform
Subarea: Scan for References and Links
Original Author:Dana Guthrie, Bentley Technical Support Group

 

 

 

 

 

 

Problem Description

User has MSJ files in ProjectWise and when he runs the scan for reference tool the references do not resolve because MicroStation V8i used by the scanref tool, opens the Msj files read only.

Steps to Resolve

  1. In MicroStation on the system you will run scanref, open MicroStation, go to workspace configuration

  2. Find the variable ms_openv7 and choose edit, change the value to 3

  3. This will tell MicroStation V8i to open v7 files read write so that when the scanref tool runs the MSJ files will open read\write and process correctly.

Tags: Integration - DGN Platform, Scan for References and Links, ProjectWise Explorer Client, SELECTsupport, Problem Solving