Applies To | |||
Product(s): | ProjectWise Integration Server | ||
Version(s): | 08.11.11.111 | ||
Environment: | N\A | ||
Area: | ProjectWise Administrator | ||
Subarea: | N\A | ||
Original Author: | Bill Kenney, Bentley Technical Support Group | ||
Problem
User gets error Cannot create tables from PW Admin connector
Sees the following in the turned up pwadmin.logs
2013-03-01 15:44:09,798 ERROR [0x00001188] pwise.tms -
System.ServiceModel.CommunicationException: DMS exception. Error code:
-11705
Server stack trace:
at Bentley.ProjectWise.WCF.PWTransport.PWModule.Send(UInt64
dmsSession, Byte[] request)
at
Bentley.ProjectWise.WCF.PWTransport.PWRequestChannel.Request(Message
message, TimeSpan timeout)
at
Bentley.ProjectWise.WCF.PWTransport.PWDuplexRequestChannel.Send(Message
message, TimeSpan timeout)
Product: ProjectWise Administrator V8i
Version: 08.11.11.111
Area: Select Area, Problem ID#: 87560, Select Category
Solution
User forgot to add the patch files to the PW / BIN directory.
This file is supplied as a patch to resolve a known issue in the
ProjectWise
8.11.11 Commercial Release. This patch should be applied only to the
8.11.11.111 release of the ProjectWise Integration Server product.
To install this patch:
1. Stop the ProjectWise Integration Server service
2. Copy "Bentley.ProjectWise.WCF.PWTransport.dll" to the 'bin'
directory
of your ProjectWise Integration Server (usually
C:\Program Files\Bentley\ProjectWise\bin). Overwrite the existing
file.
3. Copy "dmskrnl.exe.config" to the 'bin' directory of your
ProjectWise
Integration Server (usually C:\Program
Files\Bentley\ProjectWise\bin).
Overwrite the existing file.
4. Start the ProjectWise Integration Server service.