Projectwise integraton, caching, or gateway service will not start

$
0
0
Current Revision posted to Content Management - Wiki by Dana Guthrie on 8/29/2013 7:57:45 PM

  
 Applies To 
  
 Product(s):ProjectWise Integration Server
 Version(s):08.11.11.559
 Environment: N/A
 Area: Integration / Caching /Gateway
 Subarea: Installation
 Original Author:dana guthrie, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

The Projectwise Caching Server v8i (SelectSeries 4) service on Local Computer started and then stopped.  Some services stop automaticaly if they are not in use by other services or programs.

Explanation

User installed the ProjecWise caching service on a server and when he tries to start the service he gets the error.  This error could occur with the Projectwise Integration service, Caching service or Gateway Service.

How to Avoid

This behavior usually indicates a port conflict. There was another application installed on the server that was using port 5800.  Once we uninstalled that application, the ProjectWise service started with no issues.

Typical the conflicting software is VNC (Virutal Network Computing)
To find the conflicting program, try using TCPview for windows or the command line netstat -a -b to find what programs are using which ports.

 

See Also

 


Error Message: ProjectWise requests are not supported

$
0
0
Revision 1 posted to Content Management - Wiki by Phil Conard on 8/29/2013 9:24:52 PM

  
 Applies To 
  
 Product(s):ProjectWise Publishing Server
 Version(s):08.11.11.16
 Environment: N/A
 Area: Installation
 Subarea: 
 Original Author:Phil Conard, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

ProjectWise requests are not supported

Explanation

When publishing a file from ProjectWise Web Explorer, an error message is displayed that ends in "ProjectWise requests are not supported"

How to Avoid

That error means that the ProjectWise Publishing Gateway isn't installed on the ProjectWise Publisher Server

 

http://communities.bentley.com/products/projectwise/content_publishing/w/wiki/5606.aspx

Error Message: ProjectWise requests are not supported

$
0
0
Revision 2 posted to Content Management - Wiki by Phil Conard on 8/29/2013 9:27:43 PM

Error Message: ProjectWise requests are not supported

installation, SELECTsupport, Error Message, ProjectWise Publishing Server

  
 Applies To 
  
 Product(s):ProjectWise Publishing Server
 Version(s):08.11.11.16
 Environment: N/A
 Area: Installation
 Subarea: 
 Original Author:Phil Conard, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

ProjectWise requests are not supported

Explanation

When publishing a file from ProjectWise Web Explorer, an error message is displayed that ends in "ProjectWise requests are not supported"

HowtoAvoid. That error means that the ProjectWise Publishing Gateway isn't installed on the ProjectWise Publisher Server.

HowtoAvoid

InstallProjectWisePublishingGatewayontheProjectWisePublisherserver

 

http://communities.bentley.com/products/projectwise/content_publishing/w/wiki/5606.aspx

Error Message: ProjectWise requests are not supported

$
0
0
Current Revision posted to Content Management - Wiki by Phil Conard on 8/29/2013 9:30:19 PM

Error Message: ProjectWise requests are not supported

installation,SELECTsupport,ErrorMessage,ProjectWisePublishingServer

  
 Applies To 
  
 Product(s):ProjectWise Publishing Server
 Version(s):08.11.11.16
 Environment: N/A
 Area: Installation
 Subarea: 
 Original Author:Phil Conard, Bentley Technical Support Group
  

 

 

 

 

 

 

 

ErrororWarningMessage

ProjectWiserequestsarenotsupported

Explanation  

 

 

 

 

 

 

 

ProblemDescription

When publishing a file from ProjectWise Web Explorer, an error message is displayed that ends in "ProjectWise requests are not supported."  That error means that the ProjectWise Publishing Gateway isn't installed on the ProjectWise Publisher Server.

HowtoAvoid

Solution

Install ProjectWise Publishing Gateway on the ProjectWise Publisher server

 

SeeAlso

http://communities.bentley.com/products/projectwise/content_publishing/w/wiki/5606.aspx

Dmsconv -mime failed

$
0
0
Current Revision posted to Content Management - Wiki by Dana Guthrie on 9/6/2013 4:09:03 PM

  
 Applies To 
  
 Product(s):ProjectWise Integration Server
 Version(s):08.11.11.111
 Environment: N/A
 Area: ProjectWise Administrator
 Subarea: MISC
 Original Author:dana guthrie, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

DEBUG dmsconv - resetting '<failed>' MIME type entries to NULL
INFO  dmsconv - 0 '<failed>' MIME entries were reset

Explanation

User has a datasource that was upgraded / converted some time ago from a previous version of Projectwise.  The user is unsure if the mime type switch to update the mime types in the datasource was run.

The user now wants to run the dmsconv –mime to update the mime types but when the command is executed, they get the above messages.

How to Avoid

What the messages are really saying is: 'I searched the datasource for MIME entries that were in the "FAILED" state and found there were none (0) that needed to be reset so there is nothing for me to do here'

There is nothing wrong hence why this is logged as an INFO line.

So the mime types are already set for the files in the datasource and you do not need to run the dmsconv -mime.

See Also

 

VPR error when opening ProjectWise Explorer Cannot initialize

$
0
0
Current Revision posted to Content Management - Wiki by Elisa Pry on 9/9/2013 8:20:25 PM

  
 Applies To 
  
 Product(s):ProjectWise Client V8i
 Version(s):08.11.05.37
 Environment: N/A
 Area: Explorer
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Problem

 VPR error when opening ProjectWise Explorer
Cannot initialize- the color quality of the Windows display settings must be set to 16 or 32 bit

Solution

 Uninstalled the spatial extension, since it wasn't needed.  That resolved the error.

See Also

Product TechNotes and FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

InRoads opens the splash screen and then hangs

$
0
0
Current Revision posted to Content Management - Wiki by Elisa Pry on 9/9/2013 8:41:27 PM

  
 Applies To 
  
 Product(s):InRoads
 Version(s):08.09.03.06
 Environment: N/A
 Area: Explorer
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Problem

InRoads opens the splash screen and then hangs - the only way out is to kill the process.

Solution

Delete the InRoads MRU list from the Registry Editor:
HKEY_CURRENT_USER\Software\Bentley\InRoadsGroup\Applications\Version 8.9\MRUList

See Also

Product TechNotes and FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

Performance issue opening AutoCAD Civil 3D document from ProjectWise

$
0
0
Revision 1 posted to Content Management - Wiki by mantas.nauseda on 9/10/2013 10:57:05 AM

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.111
 Environment: N/A
 Area: Integration - Civil 3D
 Subarea: Data Shortcuts
 Original Author:Mantas Nauseda, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

It takes really long time to open AutoCAD Civil 3D drawing from ProjectWise.

Reason

It takes quite a lot of time to load the data shortcuts from ProjectWise when using the ProjectWise Caching server to connect to the datasource – ProjectWise needs to load the file to the caching server first and then pass it to the user.

It seems that there are some issues in the ProjectWise 08.11.11.111 with this operation.

Steps to Resolve

There were some improvements in the ProjectWise performance in SS4 RU (version 08.11.11.559).

To resolve the issue you should upgrade the ProjectWise Explorer to the SS4 RU version.

 

 


Reference files are not displaying in Bentley View

$
0
0
Current Revision posted to Content Management - Wiki by Elisa Pry on 9/10/2013 12:51:59 PM

  
 Applies To 
  
 Product(s):ProjectWise Client V8i
 Version(s):08.11.07.107
 Environment: N/A
 Area: Explorer
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Problem

 Reference files are not displaying in Bentley View. 

Solution

 Reset the Primay Search Paths for Bentley View via the MS_RFDIR. The user had it set to the C: drive though the references were on the F: drive.

See Also

Product TechNotes and FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

Performance issue opening AutoCAD Civil 3D document from ProjectWise

$
0
0
Current Revision posted to Content Management - Wiki by mantas.nauseda on 9/10/2013 12:54:47 PM

Performance issue opening AutoCAD Civil 3D document from ProjectWise

SELECTsupport,ProjectWiseExplorerClient,ProblemSolving,Integration-Civil3D,DataShortcuts

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.111
 Environment: N/A
 Area: Integration - Civil 3D
 Subarea: Data Shortcuts
 Original Author:Mantas Nauseda, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

It takes really long time to open AutoCAD Civil 3D drawing from ProjectWise.

Reason

It takes quite a lot of time to load the data shortcuts from ProjectWise when using the ProjectWise Caching server to connect to the datasource – ProjectWise needs to load the file to the caching server first and then pass it to the user.

It seems that there are some issues in the ProjectWise 08.11.11.111 with this operation.

Steps to Resolve

There were some improvements in the ProjectWise performance in SS4 RU (version 08.11.11.559).

To resolve the issue you should upgrade the ProjectWise Explorer to the SS4 RU version.

 

 

Failed to get object identifier by its GUID

$
0
0
Current Revision posted to Content Management - Wiki by Elisa Pry on 9/10/2013 2:54:37 PM

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):N/A
 Environment: N/A
 Area: ProjectWise Explorer Client
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Problem

 The first time a user logs into ProjectWise Explorer they are receiving: Error 50000 "Failed to get object identifier by its GUID. Not found."

Solution

This issue may be experienced if a ProjectWise Geospatial background map has been applied to a data source and can no longer be resolved.
Take note of the data source being logged into and review your PWC.log file searching for the line immediately above the line containing “Error 50000” that provides the background map name that cannot be located.

2010-07-08 20:34:22,303 ERROR [0x00002538] pwise.spatial.navigation - Error trying to send map definition for map [Background map OverallMap] to folder [C:\Users\ROBERT~1.HOO\AppData\Local\Temp\]
2010-07-08 20:34:22,475 ERROR [0x00002538] pwise.dms - Error 50000 "Failed to get object identifier by its GUID. Not found."

Check the location in the PWadmin for spatial maps to see where they are pointing to, then check to make sure the users have at least read access to the folder and documents.

 

In another case of this issue, someone had the same working directory as another user on the same box and that caused the same problem because PW could not copy the file out to the same workdir as the file was already there from the other user. Normally we would get different error message.

 

One other thing is that in the admin the backround maps cannot have a space in the name

See Also

Product TechNotes and FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

Last Error deleting folder

$
0
0
Revision 1 posted to Content Management - Wiki by Elisa Pry on 9/10/2013 3:13:32 PM

  
 Applies To 
  
 Product(s):ProjectWise Client V8i
 Version(s):08.11.05.16
 Environment: N/A
 Area: General
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Problem

 

Solution

 

See Also

Product TechNotes and FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

Last Error deleting folder

$
0
0
Current Revision posted to Content Management - Wiki by Elisa Pry on 9/10/2013 3:13:58 PM

Last Error deleting folder

ProjectWise,SELECTsupport,ProjectWiseClientV8i,ProjectWiseCachingServer,47638

  
 Applies To 
  
 Product(s):ProjectWise Client V8i
 Version(s):08.11.05.16
 Environment: N/A
 Area: General
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Problem

 Lasterror[-1}Errordeletingfolder-can'tdeleteemptyfoldersinProjectWise

Solution 

Tofixtheproblemyouwillneedtodothefollowing:

Grablogstofindthestorageareadmsfolder,thendeleteanythinginthere.Theremightbethumbs.dbfile.

See Also

Product TechNotes and FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

Does ProjectWise use Simple or Extended MAPI function calls to send email

$
0
0
Current Revision posted to Content Management - Wiki by Elisa Pry on 9/10/2013 3:23:32 PM

  
 Applies To 
  
 Product(s):ProjectWise Client V8i
 Version(s):08.11.05.37
 Environment: N/A
 Area: Messenger
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Problem

 Does ProjectWise use Simple or Extended MAPI function calls to send email?

Solution

 The ProjectWise Messaging service (dms/aam3/src/custom/amsg) utilizes the same list provided and uses only simple MAPI.

We have 12 #defines of specific functionality/interest; in the one area
reviewed:

LPMAPILOGON          g_lpfnMAPILogon;
LPMAPILOGOFF         g_lpfnMAPILogoff;
LPMAPISENDMAIL       g_lpfnMAPISendMail;
LPMAPISENDDOCUMENTS  g_lpfnMAPISendDocuments;
LPMAPIFINDNEXT       g_lpfnMAPIFindNext;
LPMAPIREADMAIL       g_lpfnMAPIReadMail;
LPMAPISAVEMAIL       g_lpfnMAPISaveMail;
LPMAPIDELETEMAIL     g_lpfnMAPIDeleteMail;
LPMAPIFREEBUFFER     g_lpfnMAPIFreeBuffer;
LPMAPIADDRESS        g_lpfnMAPIAddress;
LPMAPIDETAILS        g_lpfnMAPIDetails;
LPMAPIRESOLVENAME    g_lpfnMAPIResolveName;

See Also

Product TechNotes and FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

Datasources not displaying in ProjectWise Explorer

$
0
0
Current Revision posted to Content Management - Wiki by Elisa Pry on 9/10/2013 3:41:04 PM

  
 Applies To 
  
 Product(s):ProjectWise Client V8i
 Version(s):08.11.07.133
 Environment: N/A
 Area: Explorer
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Problem

 Datasources not displaying in ProjectWise Explorer. You will see the plus sign then it disappears.

Solution

Once we Hard checked the Prevent UDP for DNS and Listing Network Configuration Settings | General Tab we were able to see the datasources.

Other messages we saw in the PWC.log file included:
• Error 32768 "failed to refresh DNS/datasource name cache
• 2010-08-23 12:55:35,395 ERROR pwise.netapi.routecache - cannot map gateway/endpoint
• 2010-08-23 12:55:35,395 ERROR pwise.netapi.discovery - failed to parse DNS response from host

See Also

Product TechNotes and FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 


Error deleting a folder Folder has documents

$
0
0
Current Revision posted to Content Management - Wiki by Elisa Pry on 9/10/2013 3:58:32 PM

  
 Applies To 
  
 Product(s):ProjectWise Caching Server
 Version(s):N/A
 Environment: N/A
 Area: Explorer
 Subarea: N/A
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Problem

PID 50206: Last Error [58007] Error deleting a folder. Folder has documents. A folder that has documents can..--ProjectWise: Last Error [58007] Error deleting a folder. Folder has documents. A folder that has documents can not be removed. Remove documents first.

User was unable to delete a folder that contained more than one version of a file.

Solution

 User was unable to delete a folder that contained more than one version of a file, we were required to go into ProjectWise Explorer, go into Tools - Options, then click on the settings tab and expand document list, make sure "show all versions" is enabled.  Once we did this and were able to see our versions, we were able to delete the folder that contains files with several versions.

See Also

Product TechNotes and FAQs

External Links

Bentley Technical Support KnowledgeBase

Bentley LEARN Server

Comments or Corrections?

Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

 

Error 58033 deleting files

$
0
0
Current Revision posted to Content Management - Wiki by Molly Watts on 9/10/2013 6:24:58 PM

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.111
 Environment: N/A
 Area: MISC
 Subarea: 
 Original Author:Molly Watts, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Error or Warning Message

Error 58033.  Cannot remove document file.  Either the document file has already been removed or another application is using the file.  The ProjectWise Caching Server may be stopped.

Explanation

The IP address of the caching server had changed, and the PW server was still trying to connect using the old IP address.

How to Avoid

1. Verify that the IP is valid in DNS, and in the PW Integration server's dmskrnl.cfg

2. Restart the ProjectWise integration server service to clear out the old IP from its own cache

 

Set date format for attribute fields to show in localized format

$
0
0
Current Revision posted to Content Management - Wiki by Molly Watts on 9/13/2013 12:57:48 PM

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.559
 Environment: N/A
 Area: GUI
 Subarea: 
 Original Author:Molly Watts, Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Background

When attributes contain a date value, users in the UK would like the format to show as DD\MM\YYYY instead of MM\DD\YYYY

Steps to Accomplish

  1. In ProjectWise Administrator-Environments
  2. Browse to the Environment and Attribute that is storing the date value
  3. Right click on the Attribute-Properties
  4. In the Editing tab enter date in the Format string: field
  5. The attribute will now display in ProjectWise as the format set on the users machine (in Windows Region and Language settings)

 

Command line arguments

$
0
0
Current Revision posted to Content Management - Wiki by Robert Hook [Bentley] on 9/17/2013 6:23:14 PM

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.07.133
 Environment: N/A
 Area: Monikers
 Subarea: 
 Original Author:Robert Hook, Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

ProjectWise Explorer (pwc.exe) command line arguments/switches

Switch

Item

Value Type

Description

-d

DATASOURCE

String

Data source display name

-u

USERNAME

String

Logical or single sign on user name

-p

PASSWORD

String

User password

-t

ITEMTYPE

Numeric item type

 

-v

ITEMID

Numeric item id

<OLD VAULT ID>

-I

ITEMID2

Numeric item id

 

-c

CMDID

Numeric command id

 

-o

FLAGS

Hex numeric value

 

-vn

FOLDERPATH

String literal

 

-in

ITEMNAME

String literal

 

-r

VERSION

String literal

 

-fp

FULLPATH

String literal

 

-ns

NOSPLASH

String option

 

Some common ProjectWise Explorer command line task

Open PWC with specific data source and single sign on (SSO)

pwc -d TSG-PW8117133S.bentley.com:pw8117133

Or, open PWC with specific data source and user credentials

pwc -d TSG-PW8117133S.bentley.com:pw8117133 -u admin -p admin

Then select a specific folder ID and show the folder properties

pwc -d TSG-PW8117133S.bentley.com:pw8117133 -v 187

Or, select a specific folder name relative to the "Documents" root

pwc -d TSG-PW8117133S.bentley.com:pw8117133 -u admin -p admin -vn RMH\PRT\

Then select a specific document name

pwc -d TSG-PW8117133S.bentley.com:pw8117133 -u admin -p admin -vn RMH\PRT\ -in WS2.dgn

Then check out that document

pwc -d TSG-PW8117133S.bentley.com:pw8117133 -u admin -p admin -vn RMH\PRT\ -in WS2.dgn -c 30512

Or, check out that document without showing a splash screen

pwc -d TSG-PW8117133S.bentley.com:pw8117133 -u admin -p admin -vn RMH\PRT\ -in WS2.dgn -c 30512 -ns

Then check it back in

pwc -d TSG-PW8117133S.bentley.com:pw8117133 -u admin -p admin -vn RMH\PRT\ -in WS2.dgn -c 30511

NOTES:

  • Each command line executed will open a new ProjectWise Explorer session and process only each unique argument/switch once.  E.g. Currently you cannot execute two commands (-c) for one given session of ProjectWise Explorer.
  • If you do not provide your user name (-u) and password (-p), your Windows single sign on (SSO) credentials will be used.
  • When specifying a folder name (-fn) you must include a trailing backslash in the folder name. e.g.  RMH\PRT\
  • Checking in a document may require additional comments to be provided.  This feature can be disabled if needed by your ProjectWise administrator.  There are a number of settings located in the ProjectWise administrator user settings for Audit Trail entries for comments.
  • When specifying a full path (-fp) to a folder you should not provide a trailing backslash.
  • When specifying a full path and document name (-fp) the document name will be selected (hilighted). When specifying a full path, command ids (-c) do not execute. TR#348889 has been filed to address this.

Additional Refrerence

For a list of ProjectWise command IDs it is recommended to download the latest ProjectWise SDK and locate the aawddef.h header file and look for the most current list of IDMD_ commands.  A sample list is provided from ProjectWise SELECTseries SDK below for reference.

ProjectWise Command ID

Value

Comment

IDMD_OPEN

30501

Open document. This identifier can
  also be used as a double-click action identifier.

IDMD_OPEN_WITH

30502

Open document using specified
  application. This identifier can also be used as a double-click action
  identifier.

IDMD_PRINT

30503

Print document.

IDMD_QUICKVIEW

30504

View double-clicked document in
  ProjectWise Quick View. This identifier can also be used as a double-click
  action identifier.

IDMD_NEW

30506

Create new document.

IDMD_MODIFY

30507

Modify document. This identifier
  can also be used as a double-click action identifier.

IDMD_SAVE_AS

30508

Save document as specified.

IDMD_DELETE

30509

Delete document.

IDMD_CHECKIN

30511

Check in document.

IDMD_CHECKOUT

30512

Check out document. This identifier
  can also be used as a double-click action identifier.

IDMD_COPYOUT

30513

Copy out document.

IDMD_PURGECOPY

30514

Purge local document copy.

IDMD_FREE

30515

Free document.

IDMD_SETMODIFY

30517

Modify document set attributes and
  contents.

IDMD_SETCREATE

30518

Create document set.

IDMD_REMOVE

30519

Remove document set.

IDMD_VERSION

30521

Create new document version. This
  identifier can also be used as a double-click action identifier.

IDMD_STATE

30522

Change document state.

IDMD_PROPERTIES

30525

View document properties.

NOTE: The "Properties"
  menu item is identified by #IDMD_MODIFY - this is because that functionality
  actually modifies document's properties.

IDMD_EXPORT

30526

Export document. This identifier
  can also be used as a double-click action identifier.

IDMD_REDLINE

30527

Redline document. This identifier
  can also be used as a double-click action identifier.

IDMD_REFRESH_COPY

30528

Refresh document copy.

IDMD_UPDATE_SERVER

30529

Update document in the file server.

IDMD_SEND_MAIL

30530

Send mail with document attachment.

IDMD_SEND_NOTICE

30531

Send notice with document
  attachment.

IDMD_COPY_OUT_TO

30532

Copy out document to the specified
  location. This identifier can also be used as a double-click action
  identifier.

IDMD_SET_FINAL

30533

Set final document state.

IDMD_REMOVE_FINAL

30534

Remove final document state.

IDMD_OPEN_READONLY

30535

Open document as read-only. This
  identifier can also be used as a double-click action identifier.

IDMD_UFLDRREMOVE

30536

Remove document from the custom
  hierarchy.

IDMD_CHANGE_PREV_STATE

30539

Change document state to the previous
  one.

IDMD_CHANGE_NEXT_STATE

30540

Change document state to the next
  one.

IDMD_MODIFY_ATTR

30541

Modify document attributes.

IDMD_COPY_LIST

30542

Copy document list.

IDMD_PRINT_LIST

30543

Print document list.

IDMD_COPYLIST_TABSEPARATED

30545

Copy document list with tab
  separated.

IDMD_COPYLIST_SPACESEPARATED

30546

Copy document list with space
  separated.

IDMD_IMPORT

30547

Import document back into the
  system.

IDMD_GENERATE_CODE

30548

Generate document code.

IDMD_DELETE_SHEET

30549

Delete document attribute sheet.

IDMD_CREATE_MULTIPLE

30550

Create multiple document.

IDMD_OPENVAULT

30551

Open folder in separate window.

IDMD_COPY

30552

Copy document.

IDMD_MOVE

30553

Move document.

IDMD_MEMBERIN

30554

Member In dialog open.

IDMD_MASTER_LINKS

30555

Shows master document references.

IDMD_RELEASE_MASTER

30556

Release master.

IDMD_RELEASE_REF

30557

Release references.

IDMD_COPY_ATTR_DATA

30558

Copy document attribute data.

IDMD_PASTE_ATTR_DATA

30559

Paste document attribute data.

IDMD_ADD_SHEET

30560

Add document attribute sheet.

IDMD_CLEAN_AUDITTRAIL

30561

Clean Audit Trail report.

IDMD_RENAME

30562

Rename document.

IDMD_CODE_RESERVATION

30563

Reserve document code.

IDMD_SEND_MAIL_AS_LINK

30564

IDMD_SHARED_CHECKOUT

30565

IDMD_IMPORT_FROM

30566

IDMD_ADD_COMMENT

30567

IDMD_SCAN_REFERENCES

30568

IDMD_SHOW_MARKUPS

30569

Find all markups of the selected
  document

IDMD_REFVERSION_MGR

30570

Manage reference versions

IDMD_REFVERSION_UPDATE

30571

Update reference versions to latest
  available

IDMD_CREATE_RENDITIONS

30572

Create Renditions

Revit autologins to datasource

$
0
0
Current Revision posted to Content Management - Wiki by mantas.nauseda on 9/18/2013 5:30:44 AM

  
 Applies To 
  
 Product(s):ProjectWise Explorer Client
 Version(s):08.11.11.559
 Environment: N/A
 Area: Integration - Revit
 Subarea: Auto Login to datasource
 Original Author:Mantas Nauseda, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

When using the ProjectWise application (like AutoCAD, Revit or MicroStation) and trying to open the document (from inside of application) it logs in automatically to one of the datasources.
Opening ProjectWise Network Configuration does not show any settings of autologin defined.

Reason

Most likely in previous versions of ProjectWise the autologin settings were saved in the Crrent User registry (HKCU). After upgrading to ProjectWise SS4 Refresh Update the Network Configuration Settings requires the administrator rights to start and as a result the settings are saved/loaded from the Local Machine (HKLM).

This results that the Network Configuration does not show any settings defined, but the application loads these settings from HKCU and logs in to datasource automatically.

Steps to Resolve

  1. Open Registry editor
  2. Navigate to: HKEY_CURRENT_USER\Software\Bentley\ProjectWise iDesktop Integration\08.11\AutoLogin
  3. This key stores all autologin details
  4. Delete all the autologin settings from current user
  5. If needed use the ProjectWise Network configuration to define the required autologin settings.

 

Viewing all 1890 articles